Upload Media To shall be “Local Storage”.
The camera has the capability to buffer up to 3 seconds of video at any time, so that we can include
these 3 seconds of video to the file, to capture the moment right before the event occurred. With the
settings of:
Pre-Buffer Time = 3;
Upload Period = 57
the length of the video clip will be 1 minute.
You can freely decide the name of the file. Whatever name you choose, the camera will automatically
append milliseconds in the end. It is recommended to include day code in file name so that later when
the files are downloaded to remote computer, it is easier to pick up the right video.
For example, you may consider using following file name:
vid_%YYYY-%MM-%DD-%hh-%mm-%ss
where %YYYY displays current year, %MM displays current month, %DD displays current day, %hh
displays current hour, %mm displays current minute and %ss displays current second.
Note: Please note that the camera uses its own date and time settings to write the file name, so please
make sure the camera’s date and time are correct!
Upload Path can be simply “\”, which means that the files will be saved in root folder of the storage.
The video source can be either “1” or “2”. If you want to have different video parameters for remote NVR
recording and Local Storage recording, then you may consider adjusting camera’s media 1 and media 2
settings accordingly and then choose the right video source in Event Handler page.
When done, just press “Apply” and move on to the “Event List”, and pick any of the empty spots in the
list of rules to create a new rule. In our example, we pick the rule 3 for setup.
Make sure to have the rule “Enabled” by filling the checkbox.